Since it is possible to manufacture Light Emitting Diodes in a wide variety of colors and brightness, it is also necessary to accurately measure their optical characteristics.

There are two ways of measuring LED's, photometry and radiometry. Photometry only relates to visible radiation, like the human eye response. Radiometry is not limited to the human eye response. In both photometry and radiometry, the LED can be characterized in emitted power or in the intensity. The emitted power is all the power (flux) emitted from the LED in lumens or watts,

collected and measured without regards to the direction of the flux. The intensity is the flux per unit solid angle directed toward the observer, usually along the axis of the LED and is given in candela's. Because of their size, LED's are very difficult to mask and standards are not currently available defining how such measurements should be performed. Careful consideration in the design and use of LED test and measurement equipment is essential to achieve valid measurement results that fit the application.

The simplest and quickest way to measure the total luminous flux from an LED is to use an integrating sphere, coupled to an Avantes spectrometer. The integrating sphere is a simple device for measuring optical radiation. The interior surface of the integrating sphere is perfectly diffusing and has spatially uniform reflectance. The radiant exchange from diffuse surface to diffuse surface integrates the light, resulting in equal radiance at any point on the sphere wall. The system can be calibrated with a halogen light source AvaLight-HAL-CAL-ISP. With AvaSoft-IRRAD

spectrometer software it is possible to calculate the parameters from the measured spectral distribution and to perform an absolute irradiance measurement. Also the intensity of the measured light can be calculated, displayed and saved as spectral irradiance in μWcm-2nm-1. Further, the following output parameters are displayed in a separate window: radiometric quantities μW/cm▓, μJoule/cm▓, μWatt or μJoule, photometric quantities Lux or Lumen, color coordinates X, Y, Z, x, y, z, u, v and color temperature. In addition raw data in Scope mode is displayed as well as the X-Y Chromaticity diagram, including parameters, specially useful for LED measurements, such as: Dominant Wavelength, Purity, Central Wavelength, Peak Wavelength, Centro´d, etc.

Categories

Amplifier
Generator
New Era Pumps
Spellman High Voltage Supplies
Glass Chemical Reactors
High Pressure Autoclave
Solar Test System
Microfluidics Devices
Confocal Raman Microscope
Four Point Probe
Potentiostat / Galvanostat / ZRA
Hall Effect Measurement
High Pressure Homogenizer
Battery Cycler
Cryogenics
Avantes Spectrophotometers
  SensLine Spectrometers
  Software
  StarLine Spectrometers
  Light Source
  NIRLine Spectrometers
  CompactLine Spectrometers
  Fiber Optics Sensors
  Accessories
  OEM Spectrometers
  Applications
  Spectrometer Systems
  Spectrometer Accessories

Information

About Us
Contact Us
Privacy Notice